P SERIES
P Series Selection Procedure and Service Factors
The P catalog selects a unit in two steps: first the type and size from the ratio and the nominal power rating, with a check of maximum torque and actual ratio; then the utilization and the required thermal capacity. The steps, formulas and factor tables follow.
Selection steps
| Step |
|---|
| 1. Determination of gear unit type and size |
| 1.1 Find the transmission ratio |
| 1.2 Determine the nominal power rating of the gear unit |
| 1.3 Check for maximum torque, e. g. peak operating-, starting- or braking torque |
| Gear unit sizes and number of gear stages are given in rating tables , depending on iN and PN |
| 1.4 Check whether the actual ratio i as per tables on pages 037-039 |
| 2. Determination of gear unit utilization and required thermal capacity PG |
| 2.1 Gear unit utilization for the determination of the thermal capacity(in %) |
| The f14 factor can be calculated from table 5, page 014, as a function of the percentage utilization |
| 2.2 Adequate for gear units without auxiliary cooling, if: |
| 2.3 For higher thermal capacities, cooling by external air cooler or water cooler on request |

Table 1: service factor f1 for the driven machine
| Industry | Driven machine | ≤0.5 h/day | >0.5–10 h/day | >10 h/day |
|---|---|---|---|---|
| Waste watertreatment | Thickeners | – | – | 1.2 |
| Waste watertreatment | Filter presses | 1 | 1.3 | 1.5 |
| Waste watertreatment | Flocculation apparata | 0.8 | 1 | 1.3 |
| Waste watertreatment | Aerattors | – | 1.8 | 2 |
| Waste watertreatment | Raking equipment | 1 | 1.2 | 1.3 |
| Waste watertreatment | Combined longitudinal and rotary rakes | 1 | 1.3 | 1.5 |
| Waste watertreatment | Pre-thickeners | – | 1.1 | 1.3 |
| Waste watertreatment | Screw pumps | – | 1.3 | 1.5 |
| Waste watertreatment | Water turbines | – | – | 2 |
| Waste watertreatment | Centrifugal pumps | 1 | 1.2 | 1.3 |
| Waste watertreatment | 1 piston volume type pump | 1.3 | 1.4 | 1.8 |
| Waste watertreatment | If more than 1 piston volume type pump | 1.2 | 1.4 | 1.5 |
| dredgers | Bucket conveyors | / | 1.6 | 1.6 |
| dredgers | Dumping devices | / | 1.3 | 1.5 |
| dredgers | Carterpillar | 1.2 | 1.6 | 1.8 |
| dredgers | Bucket wheel excavators : as pick-up | / | 1.7 | 1.7 |
| dredgers | Bucket wheel excavators : for primitive material | / | 2.2 | 2.2 |
| dredgers | Cutter heads | / | 2.2 | 2.2 |
| Steel industry | wire drawing machine | 1.25 | 1.5 | 1.75 |
| Steel industry | reeling machine | 1 | 1.25 | 1.5 |
| Steel industry | centralized driving channel (without reverse rotation) | 1.25 | 1.5 | 1.75 |
| Steel industry | Individual driving channel (without reverse rotation) | 1.5 | 1.75 | 2 |
| Steel industry | centralized driving channel (with reverse rotation) | 1.75 | 2.25 | 2.5 |
| Steel industry | centralized driving channel (with reverse rotation) | 2 | 2.25 | 2.75 |
| Textile industry | loom | 1.25 | 1.5 | 1.75 |
| Textile industry | spinning machine | 1 | 1.25 | 1.5 |
| Textile industry | washing machine | 1 | 1.25 | 1.5 |
| conveyors | buckey conveyors | – | 1.2 | 1.5 |
| conveyors | hauling winches | 1.4 | 1.6 | 1.6 |
| conveyors | hoists | – | 1.5 | 1.8 |
| conveyors | belt conveyors≤150kw | 1 | 1.2 | 1.3 |
| conveyors | belt conveyors>151kw | 1.1 | 1.3 | 1.4 |
| conveyors | goods lifts* | – | 1.2 | 1.5 |
| conveyors | passenger lifts* | – | 1.5 | 1.8 |
| conveyors | apron conveyors | – | 1.2 | 1.5 |
| conveyors | escalators | – | 1.2 | 1.4 |
| conveyors | rail travelling gears | – | 1.5 | – |
| Granes | Slewing gears | 1 | 1.4 | 1.8 |
| Granes | Luffing gears | 1 | 1.4 | 1.8 |
| Granes | Travelling gears | 1.5 | 1.75 | 2 |
| Granes | Hoisting gears | 1 | 1.1 | 1.4 |
| Granes | Derricking jib cranes | 1 | 1.2 | 1.6 |
| Chemical industry | Extruders | – | – | 1.6 |
| Chemical industry | Dough mills | – | 1.8 | 1.8 |
| Chemical industry | Rubber calenders | – | 1.5 | 1.5 |
| Chemical industry | Cooling drums | – | 1.3 | 1.4 |
| Chemical industry | Mixers for,uniform media | 1 | 1.3 | 1.4 |
| Chemical industry | Mixers for,non-uniform media | 1.4 | 1.6 | 1.7 |
| Chemical industry | Blender,for medium of homogeneous density | 1 | 1.3 | 1.5 |
| Chemical industry | Blender,for medium of inhomogeneous density | 1.2 | 1.4 | 1.6 |
| Chemical industry | Baking oven | 1 | 1.3 | 1.5 |
| Chemical industry | Centrifugal machine | 1 | 1.2 | 1.3 |
| fan | Cooling tower fan | – | – | 2 |
| fan | Fan(axial flow and centrifugal type) | – | 1.4 | 1.5 |
| Cane sugar production | Cane knives | – | – | 1.7 |
| Cane sugar production | Cane mills | – | – | 1.7 |
| Beet sugar production | Beet cossettes macerators | – | – | 1.2 |
| Beet sugar production | Extraction plants,mechanicl refrigerators,juice boilers | – | – | 1.4 |
| Beet sugar production | Sugar beet washing machines | – | – | 1.5 |
| Beet sugar production | Sugar beet cutters | – | – | 1.5 |
| cableways | Material ropeways | – | 1.3 | 1.4 |
| cableways | To-and for system aerial ropeways | – | 1.6 | 1.8 |
| cableways | T-bar lifts | – | 1.3 | 1.4 |
| cableways | Continuous ropeways | – | 1.4 | 1.6 |
| Cement industry | Concrete micers | – | 1.5 | 1.5 |
| Cement industry | Breakers* | – | 1.2 | 1.4 |
| Cement industry | Rotary kilns | – | – | 2 |
| Cement industry | Tube mills | – | – | 2 |
| Cement industry | Separators | – | 1.6 | 1.6 |
| Cement industry | Roll crushers | – | – | 2 |
| Paper machines | Of all kind | – | 1.8 | 2 |
| Paper machines | Pulper drives | – | 2 | 2.25 |
| comoressor | Reciprocating comperssor | – | 1.8 | 1.9 |
| comoressor | Centrifugal copressor | – | 1.4 | 1.5 |
- Design for power rating of driven machine P2 : )designed power corresponding to max.torque.
Table 2: prime mover factor f2
| Prime mover | f2 |
|---|---|
| Electric motors, hydraulic motors, turbines | 1.0 |
| Piston engines 4 – 6 cylinders cyclic variation 1 : 100 to 1 : 200 | 1.25 |
| Piston engines 1 – 3 cylinders cyclic variation up to 1 : 100 | 1.5 |
Table 3: peak torque factor f3
| Type of load | 1-5 | 6-30 | 31-100 | >100 |
|---|---|---|---|---|
| Steady direction of load | 0.5 | 0.65 | 0.7 | 0.85 |
| Altemating direction of load | 0.7 | 0.95 | 1.1 | 1.25 |
Table 4: thermal factor f4
| Ambient temperature | 100 | 80 | 60 | 40 | 20 |
|---|---|---|---|---|---|
| 10℃ | 1.14 | 1.20 | 1.32 | 1.54 | 2.04 |
| 20℃ | 1.00 | 1.06 | 1.16 | 1.35 | 1.79 |
| 30℃ | 0.87 | 0.93 | 1.00 | 1.18 | 1.56 |
| 40℃ | 0.71 | 0.75 | 0.82 | 0.96 | 1.27 |
| 50℃ | 0.55 | 0.58 | 0.64 | 0.74 | 0.98 |
Table 5: utilization factor f14
| 30% | 40% | 50% | 60% | 70% | 80% | 90% | 100% |
|---|---|---|---|---|---|---|---|
| 0.66 | 0.77 | 0.83 | 0.90 | 0.90 | 0.95 | 1.0 | 1.0 |
General information
| Note |
|---|
| For careful selection of suitable P series planetary gear units please observe the details given in this brochure. |
| P series planetary gear units are reliable drive components for the use in different industrial sectors. |
| A fine-progression series covers a nominal torque range between 22,000 and 2,600,000 Nm. |
| The modular design permits standardization of many basic components, including both planetary gear stages and housing parts as well as input side and output side components. |
| A choice of possible gear unit combinations is set out on page 015. |
| Heavily loaded housing parts are made out of spheroidal graphite cast iron. Other materials on request |
| Sun and planet gears have spur gear teeth and are case-hardened and ground. Annulus gears are or ground, depending upon size.mostly quenched and tempered and shaped |
| Gears and shafts are exclusively supported by amply dimensioned rolling bearings.For details regarding bearing life, see page 036. |
| P series planetary gear units are supplied ready for installation, but without oil. |
| The stated quantity of oil are mean values, The exact quantity of oil depends on the marks on the oillevel monitoring equipment. |
| The gear units can be operated in any mounting position. In order to guarantee adequate lubrication, the respective mounting position must be stated (see page 006). |
| The gear units are provided with dip lubrication as a standard feature. |
| For 521, 531 (all sizes) and 511 (above size 21),A motor pump is required for lubrication of the prime mover bearings, see page 045. |
| For 900/600, 910/610, 920/620 and 930/630.To ensure lubricant supply, the oil level must be increased accordingly (oil compensating tank), see page 045. |
| The stated weights are mean values. Illustrations and dimensions are not strictly binding. All data are subject to change without notice. |
| Where ambient temperatures are lower than 0℃, the oil must be pre-heated above 0℃. Where ambient temperatures are higher than 40℃,the heat insulation and cooling should be considered. Environmental conditions such as salt water, salt-laden air, aggressive substances, dust, mud, or flying stones, excessive pressure, heavy vibrations and extreme shock loads must be disclosed. |
| The gear housings are protected against corrosion and sprayed in RAL 7000.Other color on request |
| Hollow shaft for shrink disk gear units are supplied with a shrink disk as standard, but without a guard.To prevent accidents, all rotating parts should be guarded according to safety regulations. |
Source: TANHON P series catalog (2024), p. 003, 009, 013–014. Download the P catalog (PDF)