An MP model code lists the gear unit, structure, size, motor and mounting details in a fixed order. Fields marked as omitted are left out when the standard specification applies. Page numbers (P…) refer to the MP catalog PDF.

Example codes

MP F 79 MD 39 – Y 0.55 – 4P – 180° – 1 – AM1 – 480 – M1

Gear unit with motor.

MP F 79 MD 39 – AD1 – 480 – M1

Gear unit with input shaft.

Fields in order

In exampleField
MPGear unit type
FStructure
79Type
MDCombined speed reducer (omitted for single machine)
39Model of combined speed reducer (omitted for single machine)
YMotor type
0.55Motor power
4PMotor pole
180°Angle of wiring box
1Wire inlet position (default position X omitted)
AM1Coupling flange (Omitted if it is standard specification)
480Ratio
M1Mounting position
AD1Input shaft model

Structure codes

StructureCode
Ordinary shaft extension foot installation(omitted)
Foot and hollow shaft installationAB
B5 flange installationF
B5 flange and hollow shaft installationAF
Hollow shaft installationA
B14 flange and hollow shaft installationAZ
Expansion plate installationH
Foot and expansion plate installationHB
B5 flange and expansion plate installationHF
B14 flange and expansion plate installationHZ

Motor type codes

Motor typeCode
Ordinary MotorY
Flameproof MotorYB
Direct current motorZ
Brake MotorYEJ
Multi-speed MotorYD
Variable Frequency MotorYVP
Metallurgy hoisting MotorYZ
Transduction braking MotorYVPEJ
Roll MotorYG

Defaults and references

ItemExplanation
Gear unit typeMP series parallel shaft helical gear reductor
Combined speed reducer and typesee model selection parameter form on P161-P185
Typesee model selection parameter form on P161-P189
Motor power, polesee model selection parameter form on P161-P185
Angle of wiring box, wire inlet positionIf there is no indication, the default angle of wiring box is 0°, and for the wire inlet position X, see installation form figure on Page P158-P160
Input shaft modelsee model selection parameter form on P186-P189
Coupling flangeAM1 rigid connection; Connection of AM flexible coupler(Please contact the technical department of our company for size details)
Ratiosee model selection parameter form on P161-P189
Mounting positionM1, M2, M3, M4, M5, M6, If there is no indication, the product is supplied according to M1.see installation form figure on Page P158-P160